Add to Cart
Auto Power Off Digital Earth Resistance Tester Clamp for 4 Pole Soil Resistivity Testing
Quick Detail:
Features:
Description:
Advanced earth Resistance Tester YH302
The YH302 is advanced intelligent Earth Resistance Tester, which is used to measure grounding resistance for grounding pole connected to some conductive part
of facility in the power distribution unit of power circuit or building structure, for working grounding (the power distribution unit of power circuit is setting some earth
electrode for good operating condition), for safeguard grounding( if the insulation is damaged, the metal case of electric facility and the construct rack of the power distribution unit or electric pole tower may
be electrified. Therefor, setting safeguard grounding to prevent person and facility from electric damage), for safeguard grounding for the thunder and lightning
(It is seted for thunderstruck safeguard facility is discharg), for static electricity safeguard grounding (to prevent the inflammable oil, natural gas tin and pipe from
static electricity danger). For grounding pole (It is metal conductor that is buried in the soil and directly in
touched with earth), for grounding wire(It is used to connect the ground terminal of electric facility to grounding pole), and for the Grounding Net (It is Large-Size horizontal net grounding unit that is consist of vertial grounding pole
and horizontal grounding pole used for Power House,
Transformer Station. The grounding unit has discharge function and Stabilize voltage ) The tester used for the
furnish power, transformer station , it's rated AC voltage up to 500KV.
Specifications
Test mode |
voltage |
frequency: |
resistance |
3 pole & 4 pole |
AC 20V/48V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω ~ 300kΩ ±(5%rdg+5dgt) |
3 pole & 4 pole with Current Clamp |
AC 20V/48V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω~19.99kΩ ±(5%rdg+5dgt) |
Double Clamp |
AC48V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω~150Ω ±(10%rdg+5dgt) |
2 pole R~ |
AC20V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω ~ 300kΩ ±(5%rdg+5dgt) |
2 pole /4pole R |
DC20V |
|
0.02Ω ~ 3kΩ ±(5%rdg+5dgt) |
RK (compensation measurement for wire resistance) |
AC20V/48V DC/20V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω~29.99Ω ±(5%rdg +5dgt) |
Test Short Current |
≤ 250 mA |
||
Soil resistivity |
AC20V/48V |
94Hz;105Hz;111Hz;128Hz;AFC |
0.02Ω·m~1000kΩ·m ±(5%rdg+5dgt) |
Disturb Voltage; Current and Frequency |
Voltage ±1V~±50VDC/AC±(5%rdg+5dgt) Frequency 16Hz~400Hz ±1%rdg+2dgt Current: 20mA~2A;±(5%rdg+5dgt) |
||
USB2.0 interface |
|||
Data Storage |
Manually store 100 groups |
||
Power Supply |
LR14×6; Voltage:9V Recharge Battery:Ni~MH recharge Battery, 7.2V Charger: Input voltage:100V~240V Frequency:50Hz~60Hz Output Voltage:12VDC3A |
||
Display |
LCD display, with Back light. Max 9999 |
||
Dimension |
230(W)×125(H)×284(L)mm |
||
Weight |
Approx. 2.5kg |